Cutler Hammer BRFPP Filler Plate GROUND BAR 7 HOLE CONSUMER PK GE THFILLER Rectangle Filler Plate
Plastic (snap-in) for type BR 1" space. May also be used with 400 amp and 600 amp load centers. For grounding copper or aluminum terminals in a GE load center. Offers 4 small holes for 14 - 8 AWG copper or 12 - 8 AWG aluminum terminals and 3 large holes for 14 - 4 AWG copper or 12 - 4 AWG aluminum terminals. UL Listed and ANSI Certified. 6.875" height x 2.875" width x 0.5" depth, .105 lb. Covers circuit breaker knock outs that have been removed in error.  Two 1" and two 1/2" plates.
LUG KIT NO6-2/0 NEUTRAL/GROUND Schneider PK3GTA-1CP Ground Bar Kit Square D QO70AN Auxiliary Neutral Lug Kit
For use with wire range 6-2/0. Can be mounted on any neutral or ground position by simply removing the termination screw. UL Listed. 2.875" height x .75" width x  6.875" depth, .07 lb. Used in load centers, CSED devices and NQOD and NF panel boards. Each terminal accepts (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire. NOTE - Consult local code for correct application of ground bar kit for service entrance equipment. ANSI Certified and UL Listed. Made for QO load centers. Field installed for number 12 - 2 Al or number 14 - 4 Cu wire. QO accessories can only be used with QO load centers.
Square D QOFPCP Filler Plate GROUND BAR 24 HOLE PM-GOLD PK Square D HOMFPCP Filler Plate
Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified. Used for additional grounding as required by local code. Compatible with most load center enclosures. Fits solid or stranded 4 - 14 copper wire and 10 - 12 aluminum wire. Includes mounting screws. UL Listed and ANSI Certified. 11" height x 3.5" width x 0.5" depth, .304 lb. Fills opening in covers if twistout is removed in error. QOFPCP are used only in QO load centers, filling the spaces where no circuit is attached. CHOMFPCP are for use only in Homeline load centers. UL Listed and ANSI Certified.
Square D HOM100AN Neutral Lug Kit Siemens EC38595 Closure Plate GE Electrical TFN60RCP AC Disconnect Switches
Breaker box neutral lug is designed for Homeline load centers. It works with number 1 - 1/0 copper and aluminum wire. UL Listed, ANSI Certified. Fits any meter socket application where a closure plate is needed. Steel enclosure. 2 pole, 3 wire, 240 volt AC, rated 10 HP. For central air conditioner. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. 4-3/4" x 7-1/2" x 2". UL1429 enclosure pullout switch, UL Listed.
Eaton DPU222RP Type ACD Non-Fusible Pullout Disconnect Switch Square D S106 Replacement Screw Siemens Energy WN2060U AC Disconnect Switches
Single phase, 2 pole, 2 wire, 240 volt AC, galvanized steel enclosure with molded case switch. Rated 3 HP at 120 volt, 10 HP at 240 volt. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. 5-3/8" x 8-3/4" x 3-1/8". UL Listed file No.E5239. Fit many types of service entrance devices and load center covers. Use them to replace lost or damaged screws. Single phase, 2 pole, 2 wire, 240 volt, rated 10 HP, steel enclosure. All lugs positioned for bottom entry and exit wiring. Easy mounting for quick installation. Pullout head can be replaced in off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. 5-5/32" x 7-5/16" x 2-7/32". UL Listed.
Square D QO2L30SC Load Center Homeline Square D HOM24L70S Load Center Cutler-Hammer DPF221RP AC Disconnect Switches
Main lug load center, indoor, 30 amp, 2 spaces/2 circuits. Accommodates both overhead and underground feed applications. 1" maximum knockout on the top and bottom of the enclosure. Comes with a doorless surface mount cover and factory installed main lugs. UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4 circuits. Maximum SCCR of 10,000 and a maximum load of 240 volts. NEMA type 1 enclosure. Expandable loadcentre capacity with the use of tandem or quad breakers. CSA approved for vertical, horizontal or inverted mounting. Accepts aluminum or copper conductors. Approved to only accept Canadian HomeLine breakers. Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved.
GE Electrical TF60RCP AC Disconnect Switches GE Electrical TPN60R1 AC Disconnect Switches Homeline Square D HOM24L70F Load Center
Steel enclosure. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. 6-1/2" x 9" x 3-1/4". UL869 service equipment, UL Listed. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. Designed to comply with code requirements for disconnecting central air conditioners and heat pumps. Open sides and top for quick installation. Impact and corrosion resistant GE Noryl thermoplastic resin. 2 pole, 3 wire, 120/240 volt AC, rated 10 HP. 5-3/4" x 8" x 3-1/8". UL1429 enclosed pullout switch, UL Listed. Main lug indoor load center, 70 amp, 2 spaces/4-circuits. NEMA type 1 enclosure with a flush mount cover. Overhead or underground feeds with 1-1/4" knockouts in both the top and bottom endwalls. Compatible with Homeline 1 pole and tandem breakers and a PK3GTA1 ground bar kit (not included). UL Listed.
PowerMark Gold TL412C Standard Load Center Cutler-Hammer AC222URNMP-A2 AC Disconnect Switches Square D L211N Safety Switches
Single-phase, three-wire, 120/240 volt AC. (4) 1" circuits or (8) 1/2" circuits. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. 10,000 AIC. 40 - 225 amp single phase devices have removable closing caps. TL load center enclosures are galvanized steel. 7-1/4" x 9" x 3". UL Listed. Single phase, 2 pole, 2 wire, 240 volt AC. Rated 3 HP at 120 volt, 10 HP at 240 volt. For top and bottom entry and exit, with provision for type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. 5" x 8-5/8" x 3-1/2". UL Listed file No. E5239. Single phase, 2 pole, 3 wire, solid neutral, 120/240 volt AC. Rated 3 HP at 240 volt AC, with metallic enclosure. Typical uses include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. 5.00" x 7.63" x 4.00". UL Listed, meets NEMA standard KS1.
Eaton BR24L70SP Load Center Eaton BR24L70FP Load Center Cutler Hammer BRL200 Main Lug Kit
Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. Style 5 box 4-1/2" x 9-7/16" x 3". UL Listed file E8741. Two pole - 200 amp - pair.
Square D QO200TRCP Molded Non-Fusible Disconnect Switch Square D L111N Fusible Light Duty Safety Switch Cutler-Hammer DPF222RP AC Disconnect Switches
For use with 75 degree Celsius wire. 2 pole, 2 wire, 240 volt AC, rated 10 HP, steel enclosure with molded case. With reliable, quick-make, quick-break operating mechanism. Suitable for use on systems with up to 10,000 RMS symmetrical amp available fault current at 240 volt AC maximum when protected by a fuse or circuit breaker rated 60 amp or less. Does not contain overcurrent protection. Ground bar bonded to back. 4-5/8" x 6-1/2" x 3-7/8". UL Listed. Single phase, 1 pole, 2 wire, solid neutral, 120/240 volt AC. Rated 2 HP at 120 volt AC, with metallic enclosure. Typical loads include workshop or hobby room, water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. UL Listed, meets NEMA standard KS1. 5.00" x 7.63" x 4.00". Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of  #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". NEMA 3R, rainproof. UL Listed, CSA Approved.
   
 